Lighting your gas fire place is crucial to be able to encounter the warmth and elegance they can give. In contrast to a traditional lumber burning up fire place, a gas fireplace is normally self-starting. Different from an electric fireplace, a gas fireplace needs usage of a pilot light to be able to fire up, much like a gas stove or water heater.
Try looking in your fireplace to determine if you find a tiny flame, which is called the initial light. If you don’t see this particular flame, then you have to first light up the pilot before you can fire up your gas fireplace.
In case you have an ornamental front panel or grill on your own gas fireplace, always take it off before lighting your pilot.
Your valves may be positioned behind a panel. If that’s the case, locate this particular panel and open it up to access your valves and buttons.
Make sure all your buttons are off and the pilot is really off.
Double check to make certain that the main gas valve and control valve are turned off. In case the main gas valve or control valve is on, switch it off and hold on no less than 5 minutes to permit just about any gas to clear just before you carry on. These crucial actions will assist you to prevent incidents with your gas fire place. Take out any inner glass doors if you have not already done this.
Smell all around the fire place to make certain that there’s no gas present that might fire up while you switch on the pilot. Be sure you sniff around close to the flooring since the gas is heavier compared to the surrounding air. If there is, permit the fireplace to air out not less than 5 minutes just before you continue. In case the gas odor does not clear and you have checked again to make sure that all valves are shut off, you will want to call a technician to ascertain if there are leaks.
If there is no gas odor present, turn the main valve on and the control valve to pilot. Press the control valve in approximately a quarter of an inch as you’re turning. If you cannot press the control valve inward utilizing just your own hand, phone a certified specialist. Do not use any equipment to attempt to press the control valve. Forcing the valve is not only a fire hazard, but may also trigger explosion.
Hold the pilot valve in not less than 15 seconds but up to thirty seconds and hit the piezoelectric spark igniter several times in an interval of once per second in order to turn the pilot light on. When the pilot light is turned on, a small flame should appear. If the pilot light will not stay on after repeated tries, phone a qualified technician.
Press the pilot valve in for 60 seconds or so to warm up your thermopile. When the thermopile has been warmed up, your burner will power up. When burner is turned on, turn the control valve to on and modify the thermostat to your chosen settings. The thermostat control might be a switch in the bottom panel, a standard light switch, dimmer, or it may be activated using a remote device.
Change the internal glass door, any kind of bottom access panel, ornamental glass panel or grill and ensure it is securely clamped to the front of your respective fire place. Enjoy your fire place!